Search icon

CHRIS BURNETT ELECTRIC, INC.

Company Details

Name: CHRIS BURNETT ELECTRIC, INC.
Legal type: Kentucky Corporation
Status: Active
Standing: Good
Profit or Non-Profit: Profit
File Date: 19 Jan 2006 (19 years ago)
Organization Date: 19 Jan 2006 (19 years ago)
Last Annual Report: 28 May 2024 (a year ago)
Organization Number: 0630096
Industry: Electric, Gas and Sanitary Services
Number of Employees: Small (0-19)
ZIP code: 40160
City: Radcliff
Primary County: Hardin County
Principal Office: 400 WEST LINCOLN TRAIL BLVD SUITE C, RADCLIFF, KY 40160
Place of Formation: KENTUCKY
Authorized Shares: 2000

President

Name Role
chris scott burnett President

Director

Name Role
chris scott burnett Director

Incorporator

Name Role
CHRIS BURNETT Incorporator

Registered Agent

Name Role
CHRIS BURNETT Registered Agent

Filings

Name File Date
Annual Report 2024-05-28
Annual Report 2023-03-16
Annual Report 2022-06-28
Annual Report 2021-02-25
Annual Report 2020-06-25
Annual Report 2019-06-20
Annual Report 2018-04-14
Annual Report 2017-04-02
Annual Report 2016-03-20
Annual Report 2015-05-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344296660 0420100 2019-06-13 BUILDING 1118 E. CHAFFEE AVE., FORT KNOX, KY, 40121
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2019-06-13
Emphasis L: FEDCONST
Case Closed 2019-06-13

Related Activity

Type Inspection
Activity Nr 1393829
Safety Yes
343938296 0420100 2019-04-17 BUILDING 1118 E. CHAFFEE AVE., FORT KNOX, KY, 40121
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-04-17
Emphasis L: FEDCONST, P: FEDCONST
Case Closed 2019-08-26

Related Activity

Type Inspection
Activity Nr 1393824
Safety Yes
Type Inspection
Activity Nr 1393826
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 III C
Issuance Date 2019-05-02
Abatement Due Date 2019-05-29
Current Penalty 1932.0
Initial Penalty 1932.0
Final Order 2019-05-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired. a) Fort Knox Army Base - Building 1118 Saber & Quill - Right back corner from the main entrance in the ball room: on or about 4/17/2019, the charging plug of the Sky Jack II 4626 Scissor Lift was not grounded exposing workers to electric shock hazard.
Citation ID 02001
Citaton Type Other
Standard Cited 19260451 G04 IV
Issuance Date 2019-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-29
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(iv): When midrails are used, employer did not ensure chain was installed at a height approximately midway between the top edge of the guardrail system and the platform surface. a) Fort Knox Army Base - Building 1118 - Saber and Quill job site: On or about 4/17/2019, the employer did not ensure the mid-rail height of the entry/exit gate on the Sky Jack II 4626 Scissor Lift was mid way between the top rail and the floor of the platform.
343915765 0420100 2019-04-05 BUILDING 297 GOLDVAULT ROAD, FORT KNOX, KY, 40121
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-04-05
Emphasis L: FEDCONST, P: FEDCONST
Case Closed 2019-07-26

Related Activity

Type Inspection
Activity Nr 1391876
Safety Yes
Type Inspection
Activity Nr 1391567
Health Yes
Type Inspection
Activity Nr 1391590
Safety Yes
Type Inspection
Activity Nr 1391877
Health Yes
Type Inspection
Activity Nr 1391606
Safety Yes
Type Inspection
Activity Nr 1391563
Safety Yes
Type Inspection
Activity Nr 1391554
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260405 D
Issuance Date 2019-05-02
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-05-29
Nr Instances 1
Nr Exposed 25
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(d): Switchboards and panel boards. Panel boards mounted in cabinets, cutout boxes, or enclosures designed for the purpose and were not dead front. a) Fort Knox Army Base - Building 297 located at 127 Gold Vault Road in Fort Knox, Kentucky - 1st floor - main hallway at the east wing entrance: The power panel cabinet supplying power to the job site was not dead front exposing workers to electrical shock hazards.
Citation ID 02001
Citaton Type Other
Standard Cited 19260404 F01 IV A
Issuance Date 2019-05-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-05-29
Nr Instances 4
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(1)(iv)(A): AC systems, 50 volts to 1000 volts. AC systems of 50 volts to 1000 volts were not grounded if the system can be so grounded that the maximum voltage to ground on the ungrounded conductors does not exceed 150 volts: a) Fort Knox Army Base - Building 297 located at 127 Gold Vault Road in Fort Knox, Kentucky - 1st floor - main hallway at the east wing entrance: On or about 4/5/2019, the two GFCI receptacles on the left side of each quad receptacle had an open ground. b) Fort Knox Army Base - Building 297 located at 127 Gold Vault Road in Fort Knox, Kentucky - 1st floor - main hallway at the west wing entrance: On or about 4/5/2019, the two GFCI receptacles on the left side of each quad receptacle had an open ground.
301417085 0419000 2009-09-21 2611 10TH ARMOR DIVISION ROAD, FORT KNOX, KY, 40121
Inspection Type FollowUp
Scope NoInspection
Safety/Health Health
Emphasis S: COMMERCIAL CONSTR, S: ELECTRICAL
Case Closed 2009-09-21

Related Activity

Type Inspection
Activity Nr 301416350
301416350 0419000 2008-06-24 2611 10TH ARMOR DIVISION ROAD, FORT KNOX, KY, 40121
Inspection Type Prog Related
Scope Complete
Safety/Health Health
Close Conference 2008-06-25
Emphasis S: ELECTRICAL, S: COMMERCIAL CONSTR
Case Closed 2009-09-29

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2008-11-25
Abatement Due Date 2008-12-10
Current Penalty 225.0
Initial Penalty 225.0
Nr Instances 1
Nr Exposed 3
Gravity 01
301416459 0419000 2008-06-24 2611 10TH ARMOR DIVISION ROAD, FORT KNOX, KY, 40121
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2008-06-25
Emphasis S: ELECTRICAL, L: FALL, S: COMMERCIAL CONSTR
Case Closed 2009-01-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2008-10-29
Abatement Due Date 2008-11-03
Current Penalty 900.0
Initial Penalty 1500.0
Nr Instances 2
Nr Exposed 5
Gravity 10

Sources: Kentucky Secretary of State