347580110
|
0420100
|
2024-06-25
|
354 HOLLINGER RD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-06-26
|
Emphasis |
L: MARITIME
|
Related Activity
Type |
Inspection |
Activity Nr |
1758060 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100304 B03 II A |
Issuance Date |
2024-11-08 |
Abatement Due Date |
2024-12-30 |
Current Penalty |
4968.6 |
Initial Penalty |
7098.0 |
Final Order |
2024-12-09 |
Nr Instances |
3 |
Nr Exposed |
17 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel. a) Old Admin Barge, lower hull, East of carpentry shop: On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees. b) Old Admin Barge, shed, North side of barge by dry dock: On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees. c) Old Admin Barge, lower hull, West side below material storage area: On or about June 25, 2024, and at times prior, the employer exposed employees to electrical shock hazards, in that GFCI equipped receptacles were removed and replaced with non-GFCI receptacles where sump pumps used to remove water from the barge are checked daily by employees. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19150081 B01 IV |
Issuance Date |
2024-11-08 |
Current Penalty |
8518.3 |
Initial Penalty |
12169.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.81(b)(1)(iv): The employer did not place each hose and cord in a location that would prevent injury to employees and damage to the hoses and cords. a) Facility: On or about June 25th, 2024, and at times prior, the employer exposed employees to trip and fall hazards, in that welding hoses were placed over a stairway used to access the vessel in the drydock. First Marine was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1915.81(b)(1)(iv), which was contained in OSHA inspection number 1292252, citation number 1, item number 5 and was affirmed as a final order on January 30, 2020, with respect to a workplace located at Calvert City, Kentucky. |
|
Citation ID |
03001A |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2024-11-08 |
Abatement Due Date |
2024-11-29 |
Current Penalty |
398.3 |
Initial Penalty |
569.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) Old Office barge, North-East side by metal shed: On or about June 26, 2024, and at times prior, the employer exposed employees to electric shock hazards, in that an unprotected flexible cord was used to power a sump pump and was run under a wall and through a hole in the deck. |
|
Citation ID |
03001B |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2024-11-08 |
Abatement Due Date |
2024-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
18 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: a) Old Admin barge, North-East side inside metal shed: On or about June 26, 2024, and at times prior, the employer exposed employees to electric shock hazards, in that a flexible cord used to power a sump pump was not provided with strain relief to prevent tension from being transmitted to the joints or terminal screws. |
|
|
347580151
|
0420100
|
2024-06-25
|
354 HOLLINGER RD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-06-26
|
Emphasis |
L: MARITIME
|
Case Closed |
2024-12-10
|
Related Activity
Type |
Inspection |
Activity Nr |
1758017 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1758088 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1758083 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1304227 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1758011 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19101030 F01 I |
Issuance Date |
2024-11-08 |
Abatement Due Date |
2024-11-29 |
Current Penalty |
0.0 |
Initial Penalty |
10141.0 |
Final Order |
2024-12-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(f)(1)(i): The employer did not make available the hepatitis B vaccine and vaccination series to all employees who have occupational exposure. a) Facility: On or about August 12, 2024, and at times prior, the employer exposed employees to bloodborne pathogen hazards by failing to make the Hepatitis B vaccine available to employees with a reasonably anticipated exposure to blood or other potentially infections material. First Marine was previously cited for a violation of this Occupational Safety and Health Standard 29 CFR 1910.1030(f)(i), which was contained in OSHA inspection number 1304227, citation number 1, item number 1b and was affirmed as a final order on January 30, 2020, with respect to a workplace located at Calvert City, Kentucky. |
|
|
347580177
|
0420100
|
2024-06-25
|
354 HOLLINGER RD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-06-26
|
Emphasis |
N: HEATNEP, P: HEATNEP
|
Case Closed |
2024-12-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1758088 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1758015 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1758011 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1758083 |
Health |
Yes |
|
|
347580524
|
0420100
|
2024-06-25
|
354 HOLLINGER ROAD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2024-06-26
|
Emphasis |
L: MARITIME, P: MARITIME
|
Related Activity
Type |
Inspection |
Activity Nr |
1758064 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1758060 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100025 B08 |
Issuance Date |
2024-11-08 |
Abatement Due Date |
2025-03-17 |
Current Penalty |
2839.2 |
Initial Penalty |
4056.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
1910.25(b)(8): The employer did not ensure that spiral, ship, or alternating tread-type stairs are used only when the employer can demonstrate that it is not feasible to provide standard stairs. a) First Marine, LLC, Parking Lot, Hazardous/Compressed Gas Bulk site: On or about 06-25-2024 and at times prior, the employer exposed employees to a tripping hazard, in that the stairs used by employees to access the hazardous/compressed gas storage was not installed at angles between 30 to 50 degrees. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100028 B11 II |
Issuance Date |
2024-11-08 |
Current Penalty |
2839.2 |
Initial Penalty |
4056.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements. (a) First Marine, LLC, Operational Crane Barge; on or about 06/25/2024, and at times prior, the stairs to access the crane did not have guardrails. Employer exposed employees to fall hazards. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100213 C02 |
Issuance Date |
2024-11-08 |
Current Penalty |
2839.2 |
Initial Penalty |
4056.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(2):Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) First Marine, LLC, Carpentry Shop: On or about 06-25-2024 and at times prior, the employer exposed employees to a struck -by hazard, in that the 12" table saw used by employees didn't have a spreader for cutting wood. b) First Marine, LLC, Carpentry Shop: On or about 06-25-2024 and at times prior, the employer exposed employees to a struck by hazard, in that the 10" table saw used by employees didn't have a spreader for cutting wood. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100213 C03 |
Issuance Date |
2024-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(3):Hand-fed ripsaw(s) did not have non kickback fingers or dogs designed to provide adequate holding power for all thicknesses of materials being cut: a) First Marine, LLC, Carpentry Shop: On or about 06-25-2024 and at times prior, the employer exposed employees to a struck by hazard, in that the 12" table saw used by employees didn't have kick back fingers or dogs for cutting wood. b) First Marine, LLC, Carpentry Shop: On or about 06-25-2024 and at times prior, the employer exposed employees to a struck by hazard, in that the 10" table saw used by employees didn't have kick back fingers or dogs for cutting wood. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2024-11-08 |
Current Penalty |
4258.8 |
Initial Penalty |
6084.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) First Marine, LLC, Carpentry Shop: On or about 06-25-2024 and at times prior, the employer exposed employees working in the carpentry shop to electrical and fire hazards. A 480 Volts panel box had open and unused knockouts exposing employees to contact with live parts. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
2024-11-08 |
Current Penalty |
2839.2 |
Initial Penalty |
4056.0 |
Final Order |
2024-12-09 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): a) First Marine, LLC, Crane Barge: On or about 06-25-2024 and at times prior, the employer exposed employees to electrical hazards. The extension cord that powers the bilge pumps was missing the grounding prong. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19150075 B |
Issuance Date |
2024-11-08 |
Current Penalty |
2839.2 |
Initial Penalty |
4056.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.75(b): Sides of gangways, Ramps, or permanent stairways, including those used for access to wing walls from dry dock floors did not have a railing with a midrail. (a) First Marine, LLC, second dry dock; on or about 06/26/2024, and at times prior, the stairs to access the wingwall of the drydock did not have guard rails. Employees using the wingwall of the drydock were exposed to fall hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100180 D03 III |
Issuance Date |
2024-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.180(d)(3)(iii): All safety devices for malfunction. a) First Marine, LLC, Crane Barge: on or about 06/25/2024, and at times prior, the employer exposed employees to struck by/crushing hazard, in that the crane's door had crack glass that impeded the operators situational awareness while moving loads with other employees were working in the area. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19150158 A02 |
Issuance Date |
2024-11-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-12-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.158(a)(2):Prior to each use, personal flotation devices shall be inspected for dry rot, chemical damage, or other defects which may affect their strength and buoyancy. Defective personal flotation devices shall not be used. a) First Marine, LLC: On or about 06-25-2024 and at times prior, the employer failed to ensure personal protective devices were inspected for defects which may affect their strength. An employee was using a personal protective device with nylon outer layer exposing the inside foam of the device to the environment. |
|
|
340776996
|
0420100
|
2015-07-15
|
354 HOLLINGER RD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2015-07-15
|
Emphasis |
L: MARITIME, P: MARITIME
|
Case Closed |
2015-10-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1078458 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1400.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to corrosive materials (Petter Bilge Cleaner) and were not provided suitable facilities for quick drenching or flushing of the eyes and body. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100106 B02 VII A |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
39 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(b)(2)(vii)(a): Area(s) surrounding tank(s) containing flammable liquids were not provided with adequate drainage or dikes. a) On or about 07/15/2015 and at times prior thereto, First Marine located at 354 Hollinger Rd. in Calvert City, KY had a 350 gallon above ground diesel tank on site and did not have any drainage or diking established to contain potential leakage and/or spillage. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100106 D07 III |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(d)(7)(iii): Open flames and smoking were permitted in flammable or combustible liquid storage areas. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to possible burns from smoking in area with stored flammable paints. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to welding materials and were allowed to use N95 respirators on a voluntary basis and were not provide the basic advisory information on respirators, as presented in Appendix D. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 I |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
39 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to various hazardous materials (eye, skin, and respiratory irritants) in which the employer did not compile a complete list of the hazardous chemicals known to be present. Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to bodily injury and/or disease, allergic reactions, and various irritations both internal and external. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to unlabeled hazardous materials. Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to bodily injury and/or disease, allergic reactions, and various irritations both internal and external. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19101200 G08 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
10 |
Nr Exposed |
39 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical. a) On or about 07/15/2015 and at times prior thereto, employees working at First Marine located at 354 Hollinger Rd. in Calvert City, KY were exposed to various hazardous materials (eye, skin, and respiratory irritants) in which the employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical. Without proper information on hazardous materials, employees could mis-handle hazardous materials and expose themselves to bodily injury and/or disease, allergic reactions, and various irritations both internal and external. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
|
340784586
|
0420100
|
2015-07-15
|
354 HOLLINGER RD, CALVERT CITY, KY, 42029
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-07-15
|
Emphasis |
L: MARITIME, P: MARITIME
|
Case Closed |
2015-10-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1077699 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
3400.0 |
Initial Penalty |
4900.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards. a) Bucyrus Erie Crane - On or about 7/15/15, employees were exposed to struck-by hazards when the safety latch on the hook of the Crane was missing. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19150115 A01 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
3 |
Nr Exposed |
39 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.115(a)(1): When used to transfer materials or equipment from or to a vessel, cranes which are placed onboard barges, other vessels, or on wingwalls of floating drydocks, were not tested and certified in accordance with the standards provided in 29 CFR 1919 of Hoisting and Hauling Equipment by accredited persons: a) First Marine, LLC - On or about 7/15/15, employees were exposed to struck-by and crushing hazards when cranes were not inspected annually by an accredited person. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100180 C02 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.180(c)(2): The cab(s) of crawler crane(s) were not provided with a load rating chart with clearly legible letters and figures which was easily visible to the operator while seated at the control station: (a) Bucyrus Erie Crane - On or about 7/15/15, a load chart was not available in the crane. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100180 I05 I |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.180(i)(5)(i): A carbon dioxide, dry chemical, or equivalent fire extinguisher was not kept in the cab or the vicinity of the locomotive crane(s): (a) American 7250 Crane - On or about 7/15/15, a fire extinguisher was not available in the crane. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1300.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Shop - On or about 7/15/15, employees were exposed to struck-by hazards when the point of operation on the hand grinder was not guarded. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1300.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Maintenance Shop - On or about 7/15/15, employees were exposed to struck-by hazards when the tongue guard was not adjusted properly. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19150134 B |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.134(b): Work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel. a) Maintenance Shop - On or about 7/15/15, employees were exposed to struck-by hazards when the work rest on the DeWalt bench grinder exceeded 1/8 inch. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-10-08 |
Nr Instances |
2 |
Nr Exposed |
39 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Hard-service cord and junior hard-service cord No. 14 and larger were repaired by splicing, which did not retain the insulation, outer sheath properties, and usage characteristics of the cord that was spliced:Note: Hard service flexible cords No. 12 or larger may be spliced if the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced. a) First Marine, LLC - On or about 7/15/15, employees were exposed to electrical hazards when temporary power cables were spliced together without retaining the insulating, outer sheath properties and usage characteristics of the cords being spliced In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19150056 B04 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1800.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-10-08 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.56(b)(4): Welding cable in poor condition was used. a) Dry Dock - On or about 7/15/15, employees were exposed to electrical hazards when using damaged welding cables. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19150073 D |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
2000.0 |
Initial Penalty |
3500.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 29 CFR 1915.71(j)(1) and (2). a) Dry Dock- On or about 7/15/15, employees were exposed to fall hazards when working from the top of the dry dock due to railing missing mid-rails on the end. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19150075 B |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.75(b): Sides of gangways, Ramps, or permanent stairways, including those used for access to wing walls from dry dock floors did not have a railing with a midrail. a) Dry Dock - On or about 7/15/15, employees were exposed to fall hazards when stairways used to access boats for repair were not equipped with handrails. b) Jaxon Aaron Towboat - On or about 7/15/15, employees were exposed to fall hazards when accessing the towboats due to lack of proper hand rails. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19150081 A01 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
1300.0 |
Initial Penalty |
2100.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
39 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.81(a)(1): The employer did not maintain good housekeeping practices to eliminate hazards to employees. a) First Marine, LLC - On or about 7/15/15, employees were exposed to tripping hazards when debris, tools, and materials were not cleared from walkways and working surfaces. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2015-09-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Dry Dock Control rOOM - On or about 7/15/15, employees were exposed to electrical hazards when breaker blank filler plates were not installed in unused openings in the electrical panels. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 J02 V |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
3 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered a) First Marine, LLC - On or about 7/15/15, employees were exposed to electrical hazards when an outside outlets were not protected against water accumulation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100334 A02 II |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) Floating Barge - On or about 7/15/15 , employees were exposed to electrical hazards when using damaged electrical cords. b) Maintenance Shop - On or about 7/15/15, employees were exposed to electrical hazards when using a hand grinder with a damaged cord In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19150055 A09 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
2 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.55(a)(9): Acetylene cylinders were not secured in an upright position. a) First Marine, LLC - On or about 7/15/15, employees were exposed to struck-by hazards when cylinders were not secured. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19150087 F01 |
Issuance Date |
2015-09-14 |
Abatement Due Date |
2015-10-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-10-08 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.87(f)(1): The employer did not provide an adequate number of basket stretchers , or the equivalent, readily accessible to where work is being performed on a vessel or vessel section. a) First Marine, LLC - On or about 7/15/15 a stokes basket was not available to employees. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET). |
|
|