Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-01-14
|
Emphasis |
L: MARITIME, P: MARITIME
|
Case Closed |
2020-06-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100184 I09 IV |
Issuance Date |
2020-05-14 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(i)(9)(iv): Synthetic web sling with broken or worn stitches were not immediately removed from service: a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY, On or about 14 January, 2020, a synthetic web sling that was frayed and excessively worn was not removed from service exposing employee to struck-by and/or crushing hazards in the event of a sling failure. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2020-05-14 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords or cables were used as a substitute for the fixed wiring of a structure; a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: A flexible cord or cable was providing power to the Plasma/Compressor was run thru a hole and into the plywood as a means to establish permanent wiring into the box. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV B |
Issuance Date |
2020-05-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors. a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: A power cable providing power to the Plasma/Compressor box was run thru a hole and into the plywood where it was connected to the breaker box. b) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: A power cable providing power to the Plasma/Compressor box was run thru a hole and into the plywood as a means to establish permanent wiring into the box. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
2020-05-14 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated. a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, a flexible extension cord used to provide power to hand tools, (electric grinders, electric drills and electric saws), was not grounded exposing workers to potential electric shock. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2020-05-14 |
Abatement Due Date |
2020-05-22 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following: a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, the employer did not have a written hazardous communication program to protect workers from hazardous chemicals such as but not limited to welding fumes, paints, and primers. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19150055 H |
Issuance Date |
2020-05-14 |
Abatement Due Date |
2020-05-20 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.55(h): Pressure regulators. Oxygen and fuel gas pressure regulators including their related gauges were not in proper working order while in use. a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, the regulator gauge on the Oxygen & Acetylene tanks was damaged exposing workers to serious injury from over-pressurization. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 H02 I |
Issuance Date |
2020-05-14 |
Abatement Due Date |
2020-05-20 |
Current Penalty |
325.0 |
Initial Penalty |
325.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(2)(i): All respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals, and they shall be packed or stored to prevent deformation of the facepiece and exhalation valve. a) Paducah Barge 1024 Port Authority Road, Eddyville, KY: On or about 14 January, 2020, a tight fitting elastomeric half face air-purifying respirator used during painting operations was stored in the open in a gang box exposing it to damage and contamination. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2020-05-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, the outer insulation of an extension cord was separated from the plug exposing workers to potential electrical shock. b) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, flexible cords used to power the Plasma Cutter/Air Compressor box were not protected where they enter the electrical panel box. c) Paducah Barge located at 1024 Port Authority Road, Eddyville, KY: On or about January 14, 2020, a cable leading into the main power panel the provides power to the site was not protected where it entered the panel. Worksheet: |
|
|